The structure of GYTA optical cable is that single-mode or multi-mode optical fiber is sheathed in a loose tube made of high modulus polyester material, and the tube is filled with waterproof compound. The center of the cable core is a metal reinforced core. For certain GYTA fiber cable or gyts fiber optic cable, a layer of polyethylene (PE) needs to be squeezed outside the metal reinforced core. The loose tube (and filling rope) is twisted around the central reinforcing core to form a compact circular cable core, and the gaps in the cable core are filled with water blocking fillers. Plastic-coated aluminum tape (APL) is longitudinally wrapped and then extruded into a cable with a polyethylene sheath.
As one of the professional fiber optic accessories suppliers, TUOLIMA can customize the optical cable according to your requirements. If you need any technical support, we will also recommend the most suitable and cost-effective customized ADSS fiber optical cable for you according to the use environment, laying method and terminal customer requirements of the optical cable. You can check the details of our GYTA fiber cable below. If you have any questions, feel free to consult.
cable core is a metal reinforced core. For optical cables with certain core numbers, a layer of polyethylene (PE) needs to be squeezed out of the metal reinforced core. The loose sleeve (and filling rope) is twisted around the central reinforcement core to form a compact and round cable core, and the gap in the cable core is filled with water blocking filler. Double-sided plastic coated steel strip (PSP) is longitudinally wrapped and then extruded into polyethylene sheath to form a cable.
Features
GYTA
Maximum number of tubes
Structure
Loose tubes diametermm
CSM/undercoursemm
Nominal thicknessmm
Cable diametermm
Cable unit weightkg/km
2~30core
6
1+5
Æ1.6
Æ1.45/Æ1.45
1.8±0.1
9.3±0.3
102
32~36 core
6
1+6
Æ1.6
Æ1.7/Æ1.7
1.8±0.1
9.6±0.3
110
38~60 core
12
1+5
Æ1.9
Æ1.5/Æ1.5
1.8±0.1
10.0±0.3
113
62~72 core
12
1+6
Æ1.9
Æ2.0/Æ2.0
1.8±0.1
10.5±0.3
132
74~84 core
12
1+7
Æ1.9
Æ1.45/Æ2.6
1.8±0.1
11.1±0.3
159
86~96 core
12
1+8
Æ1.9
Æ2.0/Æ3.2
1.8±0.1
11.7±0.3
159
98~108 core
12
1+9
Æ1.9
Æ2.0/Æ3.9
1.8±0.1
12.3±0.3
173
110~120 core
12
1+10
Æ1.9
Æ2.0/Æ4.5
1.8±0.1
13.0±0.3
187
122~132 core
12
1+11
Æ1.9
Æ2.0/Æ5.1
1.8±0.1
13.6±0.3
200
134~144 core
12
1+12
Æ1.9
Æ2.0/Æ5.8
1.8±0.1
14.3±0.3
219
Specification of GYTA Fiber Optical Cable
Test
Standard
Specified value
Acceptance criteria
Tension
IEC 794-1-E1
Short term (during installation): 1500NLong term (during operation): 600N
Short term tension: Every fiber in the cable elongation rate should be less than 0.33%, after the tension deleted, no fiber attenuation change happens.Long term tension: The optical fiber shall have no distinct additional attenuation and strain.
Crush
IEC 794-1-E3
Short term (during installation): 1000 N/100mmLong term (during operation): 300 N/100mm
Short term: Δα<0.2dBLong term: The optical fiber shall have no distinct additional attenuation and strain.
Impact
IEC 794-1-E4
500g, 1m
The optical fiber shall have no distinct additional attenuation and strain after test.
Repeated bending
IEC 794-1-E6
15kg
The optical fiber shall have no distinct additional attenuation and strain.
Torsion
IEC 794-1-E7
15kg, ±180°
The optical fiber shall have no distinct additional attenuation and strain.
Temperature cycling
IEC 794-1-F1
-40℃~+70℃, 2 cycles
Δα<0.2dB/km
Water penetration
IEC 794-1-F5
Sample 3m, water 1m, 24h
No water leakage
The tolerable bend radius of the cable
Dynamic (during installation):20xCable ODStatic (during operation):10xCable OD
-Fiber strain at maximum Load: max. 0.33%-Attenuation increase≤0.1dB
2
Crush test
IEC-60794-1-E3
Load:1000NTime: 1 minutesLength: 100mm
-No splits or cracks in theouter jacket;-Attenuation increase<0.1dB, (After the test)
3
Impact test
IEC-60794-1-E4
Impact energy: 450gHeight:1 meterImpact points: min.1Number of impacts: 5
-No splits or cracks in the outer jacket-Attenuation increase≤0.1dB(After the test)
4
Repeated bending
IEC-60794-1-E6
R=20×cable outer diameter1m cable length with 150N weight,30 cycles
– No splits or cracks in the outer jacket-Attenuation increase ≤0.1dB(After the test)
5
Torsiontest
IEC-60794-1-E7
1m cable length with 150N weight±180 degrees, 10 cycles
– No splits or cracks in the outer jacket-Attenuation increase ≤0.1dB(After the test)
6
Bending test
IEC-60794-1-E11
Diameter of mandrel: 20×DNumber of turns/helix:10Number of cycles: 5
– No splits or cracks in the outer jacket- No fiber break
7
Temperature cycling test
IEC-60794-1-F1
Temperature step: +20℃→-40℃→+60℃→-40℃→+60℃→+20℃Time per each step: 12 hrsNumber of cycles: 2 cycles
-Attenuation variation for reference value(the attenuation to be measured before test at +20±3℃) ≤0.1dB/km,
8
Water penetration test
IEC-60794-1-F5
Water height: 1mSample length:3mDuration of test: 24hrs
-No water leakage at the end of the sample
9
Drip test
IEC-60794-1-E14
Five 0.3m samples suspended vertically in a climate chamber, raised temperature to +70℃
-No filling compound shall drip from tubes after 24 hr
Cable parameters
Fiber Model
Tube No.
Max. fibers per tube
Cable OD. mm
Weight kg/km
Tensile resistance Long/short term N
Crush resistance Long/short term N/100m
GYTS-2~36Xn
5
12
9.2
90
600/1500
300/1000
GYTS-48~60Xn
5
12
10.0
110
600/1500
300/1000
GYTS-64~72Xn
6
12
11.0
140
600/1500
300/1000
GYTS-96Xn
8
12
12.5
160
600/1500
300/1000
GYTS-122~144Xn
12
12
15.5
280
600/2500
300/1000
Packaging
• Packing material: Non-returnable wooden drum.Both ends of cable are securely fastened to drum and sealed with a shrinkable cap to prevent ingress of moisture.
• Cable printing: The sequential number of the outdoor optical cable length shall be marked on the outer sheath of the cable at an interval of 1meter ± 1%.The following information shall be marked on the outer sheath of the cable at an interval of about 1 meter.Cable type and number of optical fiberManufacturer nameMonth and Year of ManufactureCable length
• Drum marking: Each side of every wooden drum shall be permanently marked in a minimum of 2.5~3 cm high lettering with following:Manufacture name and logoCable lengthCable type and number of fibersRoll wayGross and net weight